LumaSense Technologies, Inc. ANDROS 6511 气体仪器

分享
  • 后询价或查看价格

  • ANDROS 6511

  • 气体仪器

  • LumaSense Technologies

  • 请咨询供应商

  • LumaSense Technologies

联系销售
专家支持

The Andros 6511 offers unparalleled accuracy and performance. Now taking advantage of the latest technology, Andros brings you a product with superior performance and reliability.","The Non-Dispersive InfraRed (NDIR) sensor can measure the greenhouse gases CO2 and Methane via RS-232 communications with the host.","Every Andros 6511 NDIR bench is individually calibrated for operation from 0° C to 50° C over the entire range of specified concentrations.","The results of this intensive calibration process are stored within each system providing the most accurate analysis possible. This attention to detail provides a highly accurate factory calibration of the NDIR analyzer. Andros is so confident in our factory calibration that our customers need never calibrate the NDIR analyzer again.","The Andros 6511 is designed to meet and exceed performance requirements for portable or fixed leak detectors of toxics or combustibles.","The enhanced optics and electronics of the 6511 has virtually eliminated zero drift after the initial warm up period.","Prior to this breakthrough, frequent zeroing of an analyzer was often required during the first half-hour of operation for the most sensitive measurements. Now, with just two zeroes during the first three minutes, the new Andros 6511 is ready to meet all accuracy specifications.","The Andros 6511 optics incorporates precision beam collimating architecture.","A concentrated infrared beam generated from a proprietary emitter, passes through a precision lens into a cleanable or replaceable gold-lined sample cell that the gas of interest is flowing through.","The beam then passes into an optical assembly of highly specialized filters and a unique multi-element detector.","The 6511 embedded Operating System (OS) software has been developed to provide our customers the means to tailor a number of operations in the 6511 without the need for a custom OS. All calculations are performed in real time for transmission to your host system.

特性

  • 4气体容量
  • rs232输出
  • 流量监测压差
  • 低功率
  • 快速响应时间

ANDROS 6511 气体仪器技术参数

点击查看 0 个替代产品
规格项 参数值 勾选搜索替代
特 性
响应时间 40 seconds
环 境
工作温度 32 to 158 F (0 to 70 C)
工作湿度 95 %
物 理
安装类型 Fixed
更多技术信息
测量类型 %Volume; Trace
气体类型 Toxic; Combustible; CO2 (0.00 to 16.00%); CO (0.000 to 15.000%); Hydrocarbons (40% to 100%); H2S; Methane (CH4) / Natural Gas (40% to 100%); NO; NO2; O2 (1.01 to 25.00%); SO2
仪表类型 Monitor
应用 Process Gas
更多规格
传感技术 Electrochemical; Infrared
Number of Gases Monitored Multi
产品类别 Gas Instruments

产品替代

找到 个替代产品

环境传感器交流圈

约5圈友等你加入

    加载中···

    专家支持

    0 / 300

    选择图片

    确定提交

    提交成功

    系统自动将您的问题推送给专家解答

    查看专家解答
    请扫码进入传感圈小程序

    如何查看专家解答您的问题?

    1
    2
    3
    4