产品介绍
"Fluoride is widely added to drinking water systems to help prevent tooth decay. It is normally added in the form of liquid hydrofluorosalicic acid, which can be easily handled and applied using standard metering pumps. While the fluoridation process is often controlled by simple flow proportional feed, monitoring of final fluoride concentrations is useful in providing an alarm in the case of overfeed problems. Optimum fluoride levels of around 1 PPM are safe, but control system problems resulting in concentrations above 2 PPM are considered excessive and need to be detected as early as possible. Loss of chemical feed can also be detected quickly and reliably with on-line fluoride monitoring.","ATI’s Model A15\/82 Fluoride Monitor provides continuous measurement of free fluoride concentration in potable water. The system employs a fluoride sensitive ion selective electrode (ISE), which provides reliable measurements down to 0.1 PPM and as high as 1000 PPM. A chemistry module provides sample conditioning for the sensor, and the measured fluoride concentration is displayed on a separate electronics module that also provides alarm and analog output functions.","Fluoride ISE sensors measure F-ion in solution the same way that a pH sensor measures hydrogen ions. A lanthanum fluoride crystal on the tip of the sensor develops a voltage that is proportional to fluoride ion activity. An integral reference electrode is used as a comparator to measure the developed voltage, with the measurement made at a differential input amplifier. Since the activity of fluoride ions in solution is a function of pH and ionic strength, a small amount of buffer solution is added to the measured sample. This creates a stable condition in which the concentration of fluoride ion and the activity of fluoride ion are directly proportional.","The A15\/82 Fluoride Monitor requires very little maintenance. One gallon of buffer will operate the system for approximately 45 days. The system also performs an automatic calibration routine to correct for electrode zero drift. The fluoride standard is automatically pumped into the chemistry module and the analyzer zero is automatically adjusted. The frequency of this calibration is user-selectable from every 1 to 999 hours. Calibration standards are easily mixed from a stock solution provided with the unit, and the buffer is prepared using common vinegar."
A15&82 Fluoride Monitor 水质检测仪器技术参数
规格项 | 参数值 | 勾选搜索替代 |
更多规格 | ||
产品类别 | Water Quality Testing Instruments | |
水质参数 | Water Quality Measurement Instrument |
产品替代
声明:本产品内容及配图源自互联网收集或平台用户自行上传,目的在于传递更多信息,并不代表本网赞同其观点或证实其内容真实性,不承担此类作品侵权行为的直接责任及连带责任。如涉及作品内容、版权等问题,请联系本网处理,侵权内容将在一周内下架整改。
水质检测仪器相关品牌
水质检测仪器同类产品
加载中···