特性

  • 音频分析仪(无显示器和键盘)
  • 所有接口:模拟、数字和组合
  • 各种各样的测试功能和大量的测试信号,用于执行几乎所有的测量任务
  • 各种扫描函数
  • 超过10个加权滤波器:高通,低通,带通滤波器
  • 真正的双通道测量
  • 最大动态范围
  • 快速傅立叶分析
  • 抖动分析
  • 接口测试仪
  • 可自由编程滤波器
  • 通用的功能
  • 紧凑的单位与集成的个人电脑
  • 自动测试序列
  • 广泛的在线帮助
  • 自由可编程滤波器

The UPL66 is a 110 kHz Audio Analyzer from Rohde & Schwarz. With an audio spectrum analyzer, measure frequency response, level and gain, phase intermodulation distortion, signal-to-noise ratio, crosstalk, time domain display, and total harmonic distortion plus noise.","Additional Features:","The R&S UPL66 model is specially tailored to the requirements of production. It comes without a display and keypad, thus holding down costs. Yet the unit can be operated manually by connecting a PC keyboard and a VGA monitor, enabling fast fault localization in the event of production problems.","Audio Analyzer UPL performs practically all types of analog measurement, from frequency response measurements through to externally controlled sweeps with reference traces, determination of 3rd-order difference frequency distortion, spectral display of demodulated wow and flutter signals, etc. In contrast to many other audio analyzers, UPL is capable of performing real dual-channel measurements in the audio-frequency range, ie there is no need for switchover between two inputs and this facility is not limited to a few special cases.","The generator is every bit as versatile: it supplies any conceivable signal from sinewave and noise signals through to multi-sinewave signals comprising up to 7400 frequencies.","In addition to all this, UPL features excellent technical data: analog sine-wave generation with harmonics of typ. -120 dB, spectrum displays with a noise floor below -140 dB for analog and -160 dB for digital interfaces, FFT with a maximum frequency resolution of 0.05 Hz, etc.","UPL provides signal monitoring via loudspeaker during the test, jitter measurements on digital audio signals, resynchronization of jittered digital audio signals by means of a jitter-free clock signal, and many more features.","Superior analysis concept","UPL performs all measurements using digital signal processing. Analog signals to be tested undergo elaborate preprocessing before they are digitized and measured by means of digital routines. For example, in THD measurements, the fundamental wave is attenuated by means of a notch filter and the residual signal amplified by 30 dB before it is digitized. In this way, the dynamic range can be extended beyond that offered by the internal 20-bit converter. This provides the scope required for measuring future converters, which will be technically more advanced than present-day devices. This concept guarantees a performance and flexibility by far superior to instruments providing purely analog or digital measurements.","The above measurement concept offers many more advantages over merely analog concepts: The test routines performed on analog and digital interfaces are identical. This allows, for instance, the direct comparison of IMD measurements made ahead of and after a converter.","All test functions are available both on the analog and the digital interfaces. This makes it possible to measure at any point of a common analog and digital transmission path. Only this ensures efficient and complete testing. The filters, too, were implemented digitally, resulting in an infinite number of filters as it were, and this also for measurements on analog interfaces. Just choose the type of filter (eg highpass), cutoff frequency and attenuation: that’s all you have to do to loop a new filter into the test path.","In intermodulation measurements, spurious components are measured selectively for all frequencies in accordance with the mathematical formula of the relevant test standards. This procedure avoids the measurement of adjacent components along with the spuria, which is usually inevitable with analog test methods. Measurement speed is as a rule higher than with analog techniques since digital test routines can adapt their speed to the input frequency. Operation is the same for the analog and the digital interfaces. A feature that should not be underestimated. The intelligent combination of analog and digital measurement techniques paves the way for future applications","A future-proof investment","Nobody can accurately predict today what effects future developments in digital technology will have on the audio world and what will be the resulting test requirements. This is however no problem for Audio Analyzer UPL. Since all test functions are implemented digitally, UPL can be adapted to changing requirements by simply loading the necessary software – and this also for the analog interfaces. And one more thing: Rohde & Schwarz is the only manufacturer to equip its audio analyzers with 32-bit floating-point signal processors throughout, thus offering plenty of reserves beyond the limits of today’s common 24-bit technology.","A competent partner","The name of Rohde & Schwarz stands for excellent quality – thousands of audio analyzers have proven records at satisfied customers and have been in operation successfully for many years. After the purely analog UPA and UPD, which still holds the top position in today’s audio measurement technology, Audio Analyzer UPL has been developed to complete the program.

产品替代

找到 个替代产品

声学传感器交流圈

约6圈友等你加入

    加载中···

    专家支持

    0 / 300

    选择图片

    确定提交

    提交成功

    系统自动将您的问题推送给专家解答

    查看专家解答
    请扫码进入传感圈小程序

    如何查看专家解答您的问题?

    1
    2
    3
    4