The DPU91 transmitter provides a single channel interface for many different parameters including flow, pH\/ORP, conductivity\/resistivity, salinity and temperature. The DPU91-BC transmitter has the added capability of supporting the batch module for batching control. The extra-large (3.90 x 3.90\") autosensing backlit display can be viewed at 4 to 5 times the distance over traditional transmitters. The highly illuminated display and large characters reduce the risk of misreading or misinterpreting the displayed values. The display shows separate lines for units, main and secondary measurements as well as a dial-style digital bar graph. The DPU91 is offered in both panel or field-mount versions. Both configurations can run on 12 to 32 Vdc power (24 Vdc nominal)and have 4 to 20 mA outputs. Designed for complete flexibility, plug-in modules allow the unit to easily adapt to meet changing customer needs. Optional modules include relay, direct conductivity\/ resistivity, batch and a PC communications configuration tool. The unit can be used with default values for quick and easy programming or can be customized with labeling, adjustable minimum and maximum dial settings, and unit and decimal measurement choices.","Specifications","General Input Channels: 1 Input Types: Digital serial ASCII, TTL level, 9600 bps Frequency Range: 0.5 to 1500 Hz Accuracy: 0.5% of reading (display) Measurement Types: Flow, pH\/ORP, conductivity\/resistivity, salinity, pressure, temperature or batch Enclosure and Display Case Material: PBT Window: Shatter-resistant glass Keypad: 4 buttons, injection-molded silicone rubber seal Display: Backlit, 7 and 14-segment Update Rate: 1 second LCD Contrast: 5 settings Indicators: Dial-style digital bar graph, LEDs for open collector, relays and warning indicator Enclosure: ¼ DIN, NEMA 4X\/IP65 Mounting Panel: ¼ DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket (included) Field Mounts: Specified to OMEGA™ field mount junction boxes Weight: 0.63 kg (1.63 lb) DPU91-FLOW Series Display Ranges For conductivity\/resistivity version visit omega.com\/dpu91_conductivity For pH\/ORP version visitomega.com\/ dpu91_ph Flow Rate: -9999 to 99999 units per second, minute, hour or day Totalizer: 0.00 to 99999999 units (program lockout or resettable) Temperature: -99 to 350°C (-146 to 662°F) Volume: 0 to 99999 cm³, m³, in³, ft³, gal, L, lb, kg, % Environmental Ambient Operating Temperature: Backlit LCD: -10 to 70°C (14 to 158°F) Storage Temperature: -15 to 70°C (5 to 158°F) Relative Humidity: 0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount Maximum Altitude: 4000 m (13,123') Electrical Requirements Power to Sensors: Voltage: 4.9 to 5.5 Vdc @ 25°C, regulated short circuit protected Terminal Blocks: Pluggable screw type 14 AWG maximum wire gauge Input Power DC: 10.8 to 35.2 Vdc, regulated Current Output: 4 to 20 mA (10.8 to 35.2 VDC, 30 mA max) DPU91 without Relay Module: 200 mA @ 10.8 to 35.2 Vdc DPU91 with Relay Module: 300 mA @ 10.8 to 35.2 Vdc Open Collector: 1 Overvoltage Protection: 48 V transient protection device current limiting for circuit protection and reverse-voltage protection Relay Specifications (DPU90-R optional) Type: SPDT, Form C Maximum Current Rating: 5 A resistive 50 mA DC Maximum Voltage Rating: 30 Vdc or 250 Vac Hysteresis Adjustable: Absolute in engineering units (EUs) Latch Reset: In test screen only Delay: 9999.9 seconds (maximum) Test Mode: Set on\/off Cycle Time: 99999 seconds (maximum) Maximum Pulse Rate: 400 pulses\/minute Proportional Pulse: 400 pulses\/minute Volumetric Pulse Width: 0.1 to 3200 s Pulse Width Modulation: 0.1 to 320 s Input Types Digital or AC Frequency: pH\/ORP input via the digital output from the PHTX-2750 pH\/ORP sensor electronics (For pH models see omega.com\/ dpu91_ph) Conductivity\/Resistivity: Input directly from OMEGA conductivity\/ resistivity electrodes via direct conductivity\/resistivity module or via CDTX-2850 (For conductivity\/resistivity models see omega.com\/ dpu91_conductivity) Input Specifications Digital Serial: ACSII, TTL level, 9600 bps Frequency Input: Sensitivity: 80 mV @ 5 Hz, gradually increasing with frequency Span: 0.5 Hz to 1500 Hz @ TTL level input Accuracy: ± 0.5% or reading maximum error @ 25°C (77°F) Repeatability: ±0.2% of reading

特性

  • 大型自动感应背光显示屏
  • 表盘式数字条形图
  • 直观、用户友好的界面
  • 可选field升级继电器
  • 警告LED指示灯
  • 自定义13字符标签功能
  • 出厂重置功能
  • 拨号式数字条形图
  • 警告led指示灯

DPU91 FLOW 流量变送器技术参数

点击查看 0 个替代产品
规格项 参数值 勾选搜索替代
电 气
电气输出 Analog Current
连 接 & 显 示
接口选项 Serial/Digital
显示 Digital Display
面板接口 Digital Front Panel
更多规格
产品类别 Flow Transmitters

产品替代

找到 个替代产品

流量传感器交流圈

约12圈友等你加入

    加载中···

    专家支持

    0 / 300

    选择图片

    确定提交

    提交成功

    系统自动将您的问题推送给专家解答

    查看专家解答
    请扫码进入传感圈小程序

    如何查看专家解答您的问题?

    1
    2
    3
    4